Skip to main content
Sustainista

Sample passport — demonstration data

This passport shows what the engine produces. The economic operator, the model designation and the figures are sample content; it is not a passport issued by the manufacturer named above. Signature, content hash and version history are real and can be recomputed.

All sample passports
EU Digital Battery Passport · Regulation (EU) 2023/1542

Demo Energy Systems GmbH DemoStore IS-250

UID: ATDEMOIS2500001

Version 2 · as of 16/09/2026 · verify proof · Machine-readable (EN 18222)

Published
Public data completeness100 %

2 of 65 public data points verified

Sustainista Verified

Cryptographically sealed · v2 · 16/09/2026

100 % of all mandatory fields · Verify certificate

Issuer did:oyd:zQmQP8ADbyEfP3Ek2EvXMacxcc9nD5zADGTAZqkKX6CQPST

Public data — this page shows only publicly accessible data points (Groups A–F and M) pursuant to Art. 77(1) of the EU Battery Regulation. No login required.

A · General battery information

11 / 11 data points present

Battery identification — serial number

Anhang XIII (1a); Art. 38(6); Art. 77(3); DIN DKE SPEC 99100, 6.1.2.2

Manufacturer-provided
IS250-0001

Manufacturer identification

Annex VI-A-1; Art. 38(7)

Manufacturer-provided
name:
Demo Energy Systems GmbH
email:
kontakt@demo-energy.example
trade name:
DemoStore
web address:
https://elektro-beta.vercel.app/de/dpp/beispiele
postal address:
Speichergasse 7, 8020 Graz, AT

Battery category & model identification (Annex VI A-2)

Annex VI-A-2; Art. 38(6)

Manufacturer-provided
Industriebatterie, ortsfestes Batterie-Energiespeichersystem (> 2 kWh) · Modell DemoStore IS-250 · Aufbau 160s2p, prismatische LFP-Zellen im 10-Fuß-Schaltschrank

Place of manufacture (geographical location)

Annex VI-A-3

Manufacturer-provided
Zellfertigung: Ningde, CN (26,6617 N / 119,5478 E) · System- und Schrankmontage: Graz, AT (47,0707 N / 15,4395 E)

Date of manufacture (month & year)

Annex VI-A-4

Manufacturer-provided
2026-03-10

Battery weight (kg)

Annex VI-A-5

Manufacturer-provided
1720

Rated capacity (kWh)

Annex VI-A-6

Manufacturer-provided
250

Chemical composition

Annex VI-A-7

Manufacturer-provided
Kathode Lithium-Eisenphosphat (LiFePO4) mit Kohlenstoffbeschichtung · Anode Graphit (natürlich/synthetisch 55/45) · Elektrolyt LiPF6 in EC/DMC · Separator Polyethylen mit Keramikbeschichtung · Stromableiter Aluminium (Kathode) und Kupfer (Anode)

Hazardous substances (other than Hg, Cd, Pb)

Annex VI-A-8

Manufacturer-provided
  • name:
    Lithiumhexafluorophosphat (CAS 21324-40-3)
    anteil:
    1.9
    einheit:
    % w/w
    hinweis:
    H301, H314 — setzt mit Feuchtigkeit Flusssäure frei
  • name:
    Ethylencarbonat / Dimethylcarbonat
    anteil:
    7.4
    einheit:
    % w/w
    hinweis:
    H226 — entzündbare Flüssigkeit
  • name:
    Graphitstaub (lungengängig)
    anteil:
    9.4
    einheit:
    % w/w
    hinweis:
    Staubbelastung nur bei mechanischer Zerlegung
  • name:
    Kobalt- und Nickelverbindungen
    anteil:
    0
    einheit:
    % w/w
    hinweis:
    In der LFP-Chemie nicht enthalten — der wesentliche Unterschied zu NMC-Zellen

Suitable extinguishing agent

Annex VI-A-9

Manufacturer-provided
Wasser in großer Menge, vorrangig zur Kühlung der Module. Keine CO2- oder Pulverlöscher direkt auf die Zellen. LFP-Zellen geraten deutlich später in einen thermischen Durchgehen als NMC-Zellen, setzen dabei aber ebenfalls Flusssäure frei — Atemschutz erforderlich. Nach dem Löschen 24 h Beobachtung wegen möglicher Wiederentzündung.

Critical raw materials (> 0.1 % by weight)

Annex VI-A-10

Manufacturer-provided
  • name:
    Graphit (natürlich)
    anteil:
    9.4
    einheit:
    % w/w
  • name:
    Aluminium
    anteil:
    14.2
    einheit:
    % w/w
  • name:
    Kupfer
    anteil:
    7.8
    einheit:
    % w/w
  • name:
    Phosphor
    anteil:
    5.1
    einheit:
    % w/w
  • name:
    Lithium
    anteil:
    1.1
    einheit:
    % w/w

B · Carbon footprint

11 / 11 data points present

Carbon footprint contribution — distribution

Anhang II Nr. 8; Art. 7; DIN DKE SPEC 99100, 6.3.5

Manufacturer-provided
1.6kgCO2e/kWh

Carbon footprint contribution — end-of-life and recycling

Anhang II Nr. 8; Art. 7; DIN DKE SPEC 99100, 6.3.6

Manufacturer-provided
7.1kgCO2e/kWh

Carbon footprint contribution — main production and manufacturing

Anhang II Nr. 8; Art. 7; DIN DKE SPEC 99100, 6.3.4

Manufacturer-provided
15.8kgCO2e/kWh

Carbon footprint contribution — raw material acquisition and pre-processing

Anhang II Nr. 8; Art. 7; DIN DKE SPEC 99100, 6.3.3

Manufacturer-provided
20.5kgCO2e/kWh

Carbon footprint — declared total

Art. 7(1)(d); Annex XIII-1c

Manufacturer-provided
45

Carbon footprint performance class (A–E)

Art. 7(2); Annex II-8

Manufacturer-provided
B

Carbon footprint declaration — manufacturer details

Art. 7(1)(a)

Manufacturer-provided
Demo Energy Systems GmbH, Speichergasse 7, 8020 Graz, AT — Betreiberkennung 0088:4000000000006

Carbon footprint declaration — battery model details

Art. 7(1)(b)

Manufacturer-provided
DemoStore IS-250, 250 kWh, LFP 160s2p, Fertigungslos LOT-2026-03

Carbon footprint declaration — manufacturing plant

Art. 7(1)(c)

Manufacturer-provided
Zellfertigung Ningde, CN · System- und Schrankmontage Graz, AT

Carbon footprint declaration — EU declaration of conformity number

Art. 7(1)(f)

Manufacturer-provided
EU-KE 2026/DS-IS250/002

Carbon footprint declaration — link to the public study

Art. 7(1)(g)

Manufacturer-provided

C · Recycled content

1 / 1 data points present

Renewable content share

Anhang XIII (1f); DIN DKE SPEC 99100, 6.6.2.11

Manufacturer-provided
38

D · Responsible sourcing

10 / 10 data points present

Due diligence policy (company level)

Art. 48; Art. 49(1); Annex X-1

Manufacturer-provided
Konzernweite Sorgfaltspflichtenstrategie nach dem OECD-Leitfaden, beschlossen von der Geschäftsführung, jährlich überprüft. Zuständigkeit im Einkauf, Berichtspflicht an die Geschäftsführung, Beschwerdemechanismus öffentlich erreichbar.

Due diligence report — measures taken

Art. 52(3)

Manufacturer-provided

Due diligence report — verification summary

Art. 51; Art. 52(3)

Manufacturer-provided
Der Sorgfaltspflichtenbericht 2025 wurde von einer unabhängigen Stelle geprüft. Geprüft wurden Lieferantenstammdaten, Mengenströme und der Beschwerdemechanismus. Ergebnis: Bericht entspricht Art. 52 Abs. 3, keine wesentlichen Feststellungen.

Supply chain data — raw material description

Art. 49(2)(a)

Manufacturer-provided
  • form:
    Lithiumcarbonat, Kathodenvorstufe LiFePO4
    rohstoff:
    Lithium
  • form:
    sphärisiertes Naturgraphit und synthetisches Graphit, Anodenaktivmaterial
    rohstoff:
    Graphit
  • form:
    Kupferfolie 8 µm, Stromableiter Anode
    rohstoff:
    Kupfer
  • form:
    Aluminiumfolie 13 µm sowie Zellgehäuse und Kühlplatte
    rohstoff:
    Aluminium

Supply chain data — supplier name & address

Art. 49(2)(b)

Manufacturer-provided
  • adresse:
    Route d'Ambazac 3, 87250 Bessines, FR
    rohstoff:
    Lithium
    lieferant:
    Demo Lithium SAS
  • adresse:
    Guanggu Ave 388, Wuhan, CN
    rohstoff:
    Graphit
    lieferant:
    Demo Carbon Materials Ltd.
  • adresse:
    Werkstraße 1, 6230 Brixlegg, AT
    rohstoff:
    Kupfer
    lieferant:
    Demo Metals Austria GmbH

Supply chain data — country of origin & transactions

Art. 49(2)(c)

Manufacturer-provided
  • rohstoff:
    Lithium
    transaktion:
    Spodumen über Konverter Bessines (FR), Los LI-2025-2210
    ursprungsland:
    Australien
  • rohstoff:
    Graphit
    transaktion:
    Anodenmaterial Wuhan, Los GR-2025-8841
    ursprungsland:
    China
  • rohstoff:
    Kupfer
    transaktion:
    Walzwerk Brixlegg, 62 % Sekundärkupfer, Los CU-2025-0417
    ursprungsland:
    Österreich
  • rohstoff:
    Phosphor
    transaktion:
    Phosphorsäure über Kathodenvorstufe, Los PH-2025-1130
    ursprungsland:
    Marokko

Supply chain data — raw material quantities in the battery

Art. 49(2)(d)

Manufacturer-provided
  • menge kg:
    244.2
    rohstoff:
    Aluminium
    anteil prozent:
    14.2
  • menge kg:
    161.7
    rohstoff:
    Graphit
    anteil prozent:
    9.4
  • menge kg:
    134.2
    rohstoff:
    Kupfer
    anteil prozent:
    7.8
  • menge kg:
    87.7
    rohstoff:
    Phosphor
    anteil prozent:
    5.1
  • menge kg:
    18.9
    rohstoff:
    Lithium
    anteil prozent:
    1.1

Supply chain data — independent supplier audit

Art. 49(2)(e); Art. 50(3)

Manufacturer-provided
Unabhängiges Drittaudit der Lieferkette im Berichtszeitraum 2025 durchgeführt, Prüfbericht AUD-2025-0042. Keine wesentlichen Feststellungen; zwei Empfehlungen zur Abluftreinigung beim Graphitlieferanten sind als Vertragsbestandteil ab 2026 umgesetzt.

Supply chain data — conflict-affected and high-risk areas

Art. 49(2)(f); Annex X-4

Manufacturer-provided
Kein Bezug aus Konflikt- oder Hochrisikogebieten nach Anhang I der Verordnung (EU) 2017/821. Die LFP-Chemie kommt ohne Kobalt und Tantal aus; für Lithium, Graphit und Kupfer liegt die Lieferkette vollständig außerhalb der gelisteten Gebiete.

Evidence of recycled sources for raw materials

Art. 52(4); Annex X-1

Manufacturer-provided
Sekundäranteile sind über Materialzeugnisse der Vorlieferanten belegt: Kupferfolie 62 % Sekundärkupfer (Schmelzzeugnis Brixlegg), Aluminiumgehäuse 41 % Sekundäraluminium. Für Lithium und Graphit liegt derzeit kein Sekundäranteil vor; die Rezyklatpflicht für Aktivmaterialien beginnt am 18. August 2028.

E · Electrical characteristics

18 / 18 data points present

Cycle-life reference test

Anhang XIII (1j); DIN DKE SPEC 99100, 6.7.6.5

Manufacturer-provided
EN IEC 61427-2:2015, Prüfprofil für netzgekoppelte Speicher: 0,5 C Laden und Entladen, 80 % Entladetiefe, 25 °C Umgebungstemperatur, Abbruch bei 70 % Restkapazität

Grid connection & inverter parameters

Annex XIII Nr. 1, VO (EU) 2023/1542

Manufacturer-provided
Netzanschluss dreiphasig 400 V / 50 Hz über Wechselrichter 125 kVA. Blindleistungsstellbereich cos φ 0,90 untererregt bis 0,90 übererregt. Anschlussbedingungen nach TOR Erzeuger Typ B (Österreich) beziehungsweise VDE-AR-N 4110. Wirkungsgrad des Wechselrichters 97,8 % im Nennpunkt. Netzentkupplungsschutz nach ÖVE/ÖNORM E 8001-4-712.

Maximum permitted battery power

Anhang XIII (1e); DIN DKE SPEC 99100, 6.7.3.5

Manufacturer-provided
125000W

Self-consumption & standby losses (W)

Annex XIII Nr. 1, VO (EU) 2023/1542

Manufacturer-provided
85W

Idle temperature range — upper limit

Anhang XIII (1e); DIN DKE SPEC 99100, 6.7.7.4

Manufacturer-provided
50°C

Idle temperature range — lower limit

Anhang XIII (1e); DIN DKE SPEC 99100, 6.7.7.3

Manufacturer-provided
-20°C

Rated capacity (Ah)

Annex XIII-1g

Manufacturer-provided
490

Minimum voltage (V)

Annex XIII-1h

Manufacturer-provided
448

Nominal voltage (V)

Annex XIII-1h

Manufacturer-provided
512

Maximum voltage (V)

Annex XIII-1h

Manufacturer-provided
584

Original power capability (W)

Annex XIII-1i

Manufacturer-provided
125000

Expected lifetime (cycles & reference test)

Annex XIII-1j

Manufacturer-provided
8000

Manufacturer warranty — calendar life

Annex XIII-1m

Manufacturer-provided
10 Jahre kalendarische Lebensdauer oder 6.000 Vollzyklen, je nachdem was zuerst eintritt. Garantierte Restkapazität am Ende des Garantiezeitraums: 70 % der Nennkapazität.

Round-trip efficiency — initial value (%)

Annex XIII-1n

Manufacturer-provided
94.5

Round-trip efficiency — after 50 % of cycle life (%)

Annex XIII-1n

Manufacturer-provided
91.8

Internal resistance — cell (mΩ)

Annex XIII-1o

Manufacturer-provided
0.35

Internal resistance — pack (mΩ)

Annex XIII-1o

Manufacturer-provided
28

C-rate of the cycle-life test

Annex XIII-1p

Manufacturer-provided
0.5

F · Conformity, labelling & waste information

10 / 10 data points present

EU declaration of conformity (DoC)

Art. 18; Annex IX

Manufacturer-provided

EU declaration of conformity reference number

Art. 7(1)(f); Annex IX

Manufacturer-provided
EU-KE 2026/DS-IS250/002

CE marking (evidence of affixing)

Art. 19; Art. 20

Manufacturer-provided
true

Labelling requirements (Art. 13(3) & (4))

Art. 13(3)&(4); Annex VI Part B

Manufacturer-provided
Typenschild an der Schranktür mit Herstellerangabe, Modell, Nennkapazität, Nennspannung, Herstellungsdatum, dem Symbol der getrennten Sammlung und dem Datenträger nach EN 18220. QR-Code dauerhaft auf dem Schrankgehäuse und zusätzlich in der Anlagendokumentation.

Waste information a — end-user role & recommendations

Art. 74(1)(a)

Manufacturer-provided

Waste information b — separate collection & obligations

Art. 74(1)(b); Art. 64

Manufacturer-provided

Waste information c — take-back points & recycling facilities

Art. 74(1)(c)

Manufacturer-provided

Waste information d — safety instructions for waste batteries

Art. 74(1)(d)

Manufacturer-provided
Altbatterie nicht öffnen, Pole nicht kurzschließen, Module nicht mechanisch beschädigen. Transport nur mit isolierten Polen in zugelassener Verpackung (UN 3480). Bei sichtbarer Verformung, Geruch oder Erwärmung Sicherheitsabstand von 10 m einhalten und die Feuerwehr verständigen. Zwischenlagerung nur in Brandschutzcontainern.

Waste information e — meaning of labels & symbols

Art. 74(1)(e)

Manufacturer-provided
Durchgestrichene Abfalltonne: gehört nicht in den Restmüll. Recyclingschleife mit Prozentangabe: Anteil rezyklierten Materials. Warnzeichen Hochvolt: Freischaltung vor jedem Eingriff. Piktogramm Hand mit Buch: Anlagendokumentation vor Arbeiten lesen.

Waste information f — effects of hazardous substances on environment & health

Art. 74(1)(f)

Manufacturer-provided
Der Elektrolyt auf LiPF6-Basis reagiert mit Feuchtigkeit zu Flusssäure; Haut- und Augenkontakt vermeiden. Eisen- und Phosphatverbindungen der LFP-Kathode sind im Vergleich zu Nickel- und Kobaltverbindungen deutlich weniger gewässerschädlich, ersetzen die getrennte Erfassung aber nicht. Brandgase enthalten Fluorwasserstoff.

M

4 / 4 data points present

Economic operator identifier (ISO/IEC 6523)

prEN 18219 Abschnitt 6; prEN 18223 4.1.3.1; prEN 18239 5.2 (1); ESPR Art. 12(1), Anhang III(h)

Manufacturer-provided
0088:4000000000006

Individual battery identifier (unique ID)

Art. 77(3); Art. 13(6)

Verified
ATDEMOIS2500001

QR code (link to the battery passport)

Art. 13(6); Annex VI Part C; Art. 77(3)

Verified

Operating instructions & safety information (reference)

Art. 38(1)(a)

Manufacturer-provided
Mandatory deadline

EU Battery Passport becomes mandatory from 18 February 2027 for all EV batteries over 2 kWh (Art. 77(1), Regulation (EU) 2023/1542).

Data access

This page shows only public data (Groups A–F, M). Restricted, authority and individual data require appropriate access authorisation.

Check the address: A genuine battery passport always lives at elektro-beta.vercel.app. If a QR code takes you somewhere else, it does not belong to this passport — even if the page looks the same. This page asks for no sign-in, no input and no download; if you are asked for any of those, you are not here.

Legal basis: Regulation (EU) 2023/1542 of the European Parliament and of the Council of 12 July 2023 · Annex XIII · Art. 77 · Mandatory deadline: 18.02.2027